EPB Standards

The new set of Energy Performance of building standards, developed by CEN under mandate M/480, provides a methodology to calculate overall energy performance of buildings supporting the EPBD.

Overarching

Sub-ModulesM1 Module
GeneralEN ISO 52000-1
Common terms and definitions, symbols, units and subscriptsEN ISO 52000-1
ApplicationsEN ISO 52000-1
Ways to Express Energy PerformanceEN ISO 52003-1
Building Functions and Building BoundariesEN ISO 52000-1
Building Occupancy and Operating ConditionsEN 16798-1ISO 17772-1
Aggregation of Energy Services and Energy CarriersEN ISO 52000-1
Building ZoningEN ISO 52000-1
Calculated Energy PerformanceEN ISO 52000-1
Measured Energy PerformanceEN ISO 52000-1
Ways to express Indoor ComfortEN 16798-1ISO 17772-1
External Environment ConditionsEN ISO 52010-1
Economic CalculationEN 15459-1

Building as such

Sub-ModulesM2 Module
Building Energy NeedsEN ISO 52016-1EN ISO 52017-1
(Free) Indoor Conditions without SystemsEN ISO 52016-1EN ISO 52017-1
Ways to Express Energy PerformanceEN ISO 52018-1
Heat Transfer by TransmissionEN ISO 10077-1EN ISO 10077-2EN ISO 10211EN ISO 12631EN ISO 13370EN ISO 13789EN ISO 14683EN ISO 6946
Heat Transfer by Distribution & Control Infiltration and VentilationEN ISO 13789
Internal Heat Gains EN 16798-1ISO 17772-1
Solar Heat Gains EN ISO 52022-1EN ISO 52022-3
1 Building Dynamics (thermal mass)EN ISO 13786

Technical Building Systems (under EPBD)

Sub-ModulesM3
Heating
M4
Coolling
M5
Ventilation
M6
Humidification
M7
Dehumidification
M8
Domestic Hot Water
M9
Lighting
M10
Building Autom. & Controls
M11
Photovoltaic, Wind
GeneralEN 15316-1EN ISO 16798-9EN 16798-3EN 16798-3EN 16798-3EN 15316-1EN 15193-1EN 15232-1 
Needs     EN 12831-3EN 15193-1  
Maximum Load and PowerEN ISO 52016-1EN 12831-1EN ISO 52016-1 EN ISO 52016-1EN ISO 52016-1EN 12831-3   
Ways to Express Energy PerformanceEN 15316-1EN ISO 16798-9EN 16798-3EN 16798-3EN 16798-3EN 15316-1EN 15193-1EN 15232-1 
Emission & ControlEN 15316-2EN 15500-1EN 12098-1EN 12098-3EN 12098-5EN 15316-2EN 15500-1EN 16798-7EN 15500-1EN 16798-5-1EN 16798-5-2EN 16798-5-1EN 16798-5-2  EN 15232-1 
Distribution & ControlEN 15316-3EN 12098-1EN 12098-3EN 12098-5EN 15316-3EN 16798-5-1EN 16798-5-2  EN 15316-3 EN 15232-1 
Storage & ControlEN 15316-5EN 12098-1EN 12098-3EN 12098-5EN 16798-15   EN 15316-5EN 15316-4-3 EN 15232-1 
Generation & ControlEN 12098-1EN 12098-3EN 12098-5EN 15316-4-1EN 15316-4-2EN 15316-4-3EN 15316-4-4EN 15316-4-5EN 15316-4-8EN 16798-13EN 15316-4-2EN 15316-4-5EN 16798-5-1EN 16798-5-2EN 16798-5-1EN 16798-5-2EN 16798-5-1EN 16798-5-2EN 15316-4-1EN 15316-4-2EN 15316-4-3EN 15316-4-4EN 15316-4-5 EN 15232-1EN 15316-4-3EN 15316-4-4EN 15316-4-5EN 15316-4-10
Load Dispatching & Operating ConditionsEN 15316-1EN ISO 16798-9     EN 15232-1 
Measured Energy PerformanceEN 15378-3    EN 15378-3EN 15193-1EN 15232-1 
InspectionEN 15378-1EN 16798-17EN 16798-17EN 16798-17EN 16798-17EN 15378-1EN 15193-1EN 16946-1 
BMS       EN 16947-1 
EN ISO 52000-1

Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52000-2

Energy performance of buildings — Overarching EPB assessment — Part 2: Explanation and justification of ISO 52000-1

Published: 2017-06 Ref. Modules: M1-1, M1-2, M1-3, M1-5, M1-7, M1-8, M1-9, M1-10
EN 16798-1

Energy performance of buildings — Ventilation of buildings — Part 1: Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics

Published: 2019-05
Accompanying technical reportCEN/TR 16798-2

Energy performance of buildings — Ventilation for buildings - Part 2: Interpretation of the requirements in EN 16798-1 — Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics

Published: 2019-05 Ref. Modules: M1-6
EN ISO 52003-1

Energy performance of buildings — Indicators, requirements, ratings and certificates — Part 1: General aspects and application to the overall energy performance

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52003-2

Energy performance of buildings — Indicators, requirements, ratings and certificates — Part 2: Explanation and justification of ISO 52003-1

Published: 2017-06 Ref. Modules: M1-4
ISO 17772-1

Energy performance of buildings — Indoor environmental quality — Part 1: Indoor environmental input parameters for the design and assessment of energy performance of buildings

Published: 2017-06
Accompanying technical reportISO/TR 17772-2

Energy performance of buildings — Overall Energy performance Assessment Procedures — Part 2: Guideline for using indoor environmental input parameters for the design and assessment of energy performance of buildings

Published: 2018-04 Ref. Modules: M1-6, M1-12, M2-7
EN ISO 52010-1

Energy performance of buildings — External climatic conditions — Part 1: Conversion of climatic data for energy calculations

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52010-2

Energy performance of buildings — External climatic conditions — Part 2: Explanation and justification of ISO 52010-1

Published: 2017-06 Ref. Modules: M1-13
EN 15459-1

Energy performance of buildings — Economic evaluation procedure for energy systems in buildings — Part 1: Calculation procedures

Published: 2017-06
Accompanying technical reportCCEN/TR 15459-2

Energy performance of buildings — Economic evaluation procedure for energy systems in buildings — Part 2: Explanation and justification of EN 15459-1

Published: 2017-07 Ref. Modules: M1-14
EN ISO 52016-1

Energy performance of buildings – Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 1: Calculation procedures

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52016-2

Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1

Published: 2017-06 Ref. Modules: M2-2, M2-3, M3–3, M4–3, M6–3, M7–3
EN ISO 52017-1

Energy performance of buildings — Sensible and latent heat loads and internal temperatures — Part 1: Generic calculation procedures

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52016-2

Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1

Published: 2017-06 Ref. Modules: M2-2, M2-3, M3–3, M4–3, M6–3, M7–3
EN ISO 52018-1

Energy performance of buildings — Indicators for partial EPB requirements related to thermal energy balance and fabric features — Part 1: Overview of options

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52018-2

Energy performance of buildings — Indicators for partial EPB requirements related to thermal energy balance and fabric features — Part 2: Explanation and justification of ISO 52018-1

Published: 2017-06 Ref. Modules: M2-4
EN ISO 10077-1

Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General

Published: 2017-06
Ref. Modules: M2-5
EN ISO 10077-2

Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames

Published: 2017-06
Ref. Modules: M2-5
EN ISO 10211

Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52019-2

Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification

Published: 2017-07 Ref. Modules: M2-5
EN ISO 10211

Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52019-2

Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification

Published: 2017-07 Ref. Modules: M2-5
EN ISO 13370

Thermal performance of buildings — Heat transfer via the ground — Calculation methods

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52019-2

Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification

Published: 2017-07 Ref. Modules: M2-5
EN ISO 13789

Thermal performance of buildings — Transmission and ventilation heat transfer coefficients — Calculation method

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52019-2

Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification

Published: 2017-07 Ref. Modules: M2-5
EN ISO 13789

Thermal performance of buildings — Transmission and ventilation heat transfer coefficients — Calculation method

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52019-2

Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification

Published: 2017-07 Ref. Modules: M2-5
EN ISO 14683

Thermal bridges in building construction — Linear thermal transmittance — Simplified methods and default values

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52019-2

Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification

Published: 2017-07 Ref. Modules: M2-5
EN ISO 6946

Building components and building elements — Thermal Resistance and thermal transmittance — Calculation methods

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52019-2

Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification

Published: 2017-07 Ref. Modules: M2-5
EN ISO 12631

Thermal performance of curtain walling — Calculation of thermal transmittance

Published: 2017-06
Ref. Modules: M2-5
EN ISO 10211

Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52019-2

Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification

Published: 2017-07 Ref. Modules: M2-5
EN ISO 52022-1

Energy performance of buildings — Thermal, solar and daylight properties of building components and elements — Part 1: Simplified calculation method of the solar and daylight characteristics for solar protection devices combined with glazing

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52022-2

Energy performance of buildings — Thermal, solar and daylight properties of building components and elements — Part 2: Explanation and justification

Published: 2017-06 Ref. Modules: M2-8
EN ISO 52022-3

Energy performance of buildings — Thermal, solar and daylight properties of building components and elements — Part 3: Detailed calculation method of the solar and daylight characteristics for solar protection devices combined with glazing

Published: 2017-06
Ref. Modules: M2-8
EN ISO 13786

Thermal performance of building components — Dynamic thermal characteristics — Calculation methods

Published: 2017-06
Accompanying technical reportCEN ISO/TR 52019-2

Energy performance of buildings — Hygrothermal performance of building components and building elements — Part 2: Explanation and justification

Published: 2017-07 Ref. Modules: M2-9
EN 15316-1

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 1: General and Energy performance expression

Published: 2017-04
Accompanying technical reportCEN/TR 15316-6-1

Heating systems and water based cooling systems in buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-1: Explanation and justification of EN 15316-1

Published: 2017-04 Ref. Modules: M3-1, M3-4, M3-9, M8-1, M8-4
EN 16798-9

Energy performance of buildings — Ventilation for buildings — Part 9: Calculation methods for energy requirements of cooling systems

Published: 2017-06
Accompanying technical reportCEN/TR 16798-10

Energy performance of buildings — Ventilation for buildings — Part 10: Interpretation of the requirements in EN 16798-9

Published: 2017-07 Ref. Modules: M4-1, M4-4, M4-9
EN 16798-3

Energy performance of buildings — Ventilation for buildings — Part 3: For non-residential buildings – Performance requirements for ventilation and room-conditioning systems

Published: 2017-07
Accompanying technical reportCEN/TR 16798-4

Energy performance of buildings — Ventilation for buildings — Interpretation of the requirements in EN 16798-3

Published: 2017-07 Ref. Modules: M5-1, M5-4, M6-1, M6-4, M7-1, M7-4
EN 15193-1

Energy performance of buildings — Energy requirements for lighting — Part 1: Specifications

Published: 2017-04
Accompanying technical reportCEN/TR 15193-2

Energy performance of buildings — Energy requirements for lighting. Explanation and justification of EN 15193-1

Published: 2017-04 Ref. Modules: M9
EN 15232-1

Energy performance of buildings — Energy performance of buildings — Part 1: Impact of Building Automation, Controls and Building Management

Published: 2017-05
Accompanying technical reportCEN/TR 15232-2

Energy performance of buildings — Accompanying TR prEN 15232-1:2015

Published: 2016-09 Ref. Modules: M10-4, M10-5, M10-6, M10-7, M10-8, M10-9, M10-10
EN 12831-3

Energy performance of buildings — Method for calculation of the design heat load — Part 3: Domestic hot water systems heat load and characterisation of needs

Published: 2017-07
Accompanying technical reportCEN/TR 12831-4

Published: 2017-04 Ref. Modules: M8-2, M8-3
EN 12831-1

Energy performance of buildings — Method for calculation of the design heat load — Part 1: Space heating load

Published: 2017-07
Accompanying technical reportCEN/TR 12831-2

Energy performance of buildings — Method for calculation of the design heat load — Part 2: Explanation and justification of EN 12831-1

Published: 2017-04 Ref. Modules: M3-3
EN 15316-2

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 2: Space emission systems (heating and cooling)

Published: 2017-05
Accompanying technical reportCEN/TR 15316-6-2

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-2: Explanation and justification of EN 15316-2

Published: 2017-05 Ref. Modules: M3-5, M4-5
EN 16798-7

Energy performance of buildings — Part 7: Ventilation for buildings — Calculation methods for the determination of air flow rates in buildings including infiltration

Published: 2017-06
Accompanying technical reportCEN/TR 16798-8

Energy performance of buildings — Ventilation for buildings — Interpretation of the requirements in EN 16798-7

Published: 2017-08 Ref. Modules: M5-5
EN 16798-5-1

Energy performance of buildings — Ventilation for buildings — Calculation methods for energy requirements of ventilation and air conditioning systems — Part 5-1 Distribution and generation — Method 1

Published: 2017-05
Accompanying technical reportCEN/TR 16798-6

Energy performance of buildings — Ventilation for buildings — Part 6: Interpretation of the requirements in EN 16798-5 -1 and EN 16798-5-2

Published: 2017-07 Ref. Modules: M5–6, M5–8, M6–5, M6–8, M7–5, M7–8
EN 15500-1

Energy performance of buildings — Control for heating, ventilating and air conditioning applications — Part 1: Electronic individual zone control equipment

Published: 2017-05
Accompanying technical reportCEN/TR 15500-2

Energy performance of buildings — Control for heating, ventilating and air-conditioning applications. Accompanying TR prEN 15500-1:2015

Published: 2016-08 Ref. Modules: M3-5, M4-5, M5-5
EN 16798-5-2

Energy performance of buildings — Ventilation for buildings — Part 5-2: Calculation methods for energy requirements of ventilation systems — Method 2: Distribution and generation

Published: 2017-08
Accompanying technical reportCEN/TR 16798-6

Energy performance of buildings — Ventilation for buildings — Part 6: Interpretation of the requirements in EN 16798-5 -1 and EN 16798-5-2

Published: 2017-07 Ref. Modules: M5-6, M5-8, M6-5, M6-8, M7-5, M7-8
EN 12098-1

Energy performance of buildings — Controls for heating systems — Part 1: Control equipment for hot water heating systems

Published: 2017-05
Accompanying technical reportCEN/TR 12098-6

Controls for heating systems — Part 6: Accompanying TR prEN 12098-1:2015

Published: 2016-08 Ref. Modules: M3-5, M3-6, M3-7, M3-8
EN 12098-3

Energy performance of buildings — Controls for heating systems — Part 3: Control equipment for electrical heating systems

Published: 2017-05
Accompanying technical reportCEN/TR 12098-7

Controls for heating systems — Part 7: Accompanying TR prEN 12098-3:2015

Published: 2016-08 Ref. Modules: M3-5, M3-6, M3-7, M3-8
EN 12098-5

Energy performance of buildings — Controls for heating systems — Part 5: Start-stop schedulers for heating systems

Published: 2017-05
Accompanying technical reportCEN/TR 12098-8

Controls for heating systems — Part 8: Accompanying TR prEN 12098-5:2015

Published: 2016-08 Ref. Modules: M3-5, M3-6, M3-7, M3-8
EN 15316-3

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 3: Space distribution systems (DHW, heating and cooling)

Published: 2017-04
Accompanying technical reportCEN/TR 15316-6-3

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies - Part 6-3: Explanation and justification of 15316-3

Published: 2017-04 Ref. Modules: M3-6, M4-6, M8-6
EN 15316-5

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 5: Space heating and DHW storage systems (not cooling)

Published: 2017-05
Accompanying technical reportCEN/TR 15316-6-10

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-10: Explanation and justification of EN 15316-5

Published: 2017-04 Ref. Modules: M3–7, M8–7
EN 16798-15

Energy performance of buildings — Ventilation for buildings — Part 15: Calculation of cooling systems

Published: 2017-06
Accompanying technical reportCEN/TR 16798-16

Energy performance of buildings — Ventilation for buildings — Part 16: Interpretation of the requirements in EN 16798-15

Published: 2017-06 Ref. Modules: M4-7
EN 15316-4-3

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 4-3: Heat generation systems, thermal solar and photovoltaic systems

Published: 2017-05
Accompanying technical reportCEN/TR 15316-6-6

Energy performance of buildings — Method for calculation of system energy performance and system efficiencies — Part 6-6: Explanation and justification of EN 15316-4-3

Published: 2017-04 Ref. Modules: M3–8, M8-7, M8-8, M11–8
EN 16798-13

Energy performance of buildings — Ventilation for buildings — Part 13: Calculation of cooling systems

Published: 2017-06
Accompanying technical reportCEN/TR 16798-14

Energy performance of buildings — Ventilation for buildings — Part 14: Interpretation of the requirements in EN 16798-13

Published: 2017-06 Ref. Modules: M4-8
EN 15316-4-1

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 4-1: Space heating and DHW generation systems

Published: 2017-05
Accompanying technical reportCEN/TR 15316-6-4

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies - Part 6-4: Explanation and justification of EN 15316-4-1

Published: 2017-04 Ref. Modules: M3-7, M8-7
EN 15316-4-2

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 4-2: Space heating generation systems, heat pump systems

Published: 2017-04
Accompanying technical reportCEN/TR 15316-6-5

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-5: Explanation and justification of EN 15316-4-2

Published: 2017-04 Ref. Modules: M3-8, M8-8
EN 15316-4-4

Energy performance of buildings – Method for calculation of system energy requirements and system efficiencies – Part 4–4: Heat generation systems, building-integrated cogeneration systems

Published: 2017-04
Accompanying technical reportCEN/TR 15316-6-7

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-7: Explanation and justification of EN 15316-4-4

Published: 2017-04 Ref. Modules: M3-8, M8-8, M11–8
EN 15316-4-5

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 4-5: District heating and cooling

Published: 2017-05
Accompanying technical reportCEN/TR 15316-6-8

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-8: Explanation and justification of EN 15316-4-5

Published: 2017-04 Ref. Modules: M3-8, M4-8, M8-8, M11-8
EN 15316-4-10

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 4–10: Wind power generation systems

Published: 2017-05
Ref. Modules: M11-8
EN 15316-4-8

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 4-8: Space heating generation systems, air heating and overhead radiant heating systems, including stoves (local)

Published: 2017-04
Accompanying technical reportCEN/TR 15316-6-9

Energy performance of buildings — Method for calculation of system energy requirements and system efficiencies — Part 6-9: Explanation and justification of EN 15316-4-8

Published: 2017-05 Ref. Modules: M3-8, M8-8, M11-8
EN 15378-3

Energy performance of buildings — Heating and DHW systems in buildings — Part 3: Measured energy performance

Published: 2017-04
Accompanying technical reportCEN/TR 15378-4

Energy performance of buildings — Measured energy performance — Part 4: Explanation and justification of EN 15378-3

Published: 2017-05 Ref. Modules: M3-10, M8-10
EN 15378-1

Energy performance of buildings — Heating systems and DHW in buildings — Part 1: Inspection of boilers, heating systems and DHW

Published: 2017-05
Accompanying technical reportCEN/TR 15378-2

Energy Performance Of Buildings — Heating Systems And Dhw In Buildings — Part 2: Explanation and justification of EN 15378-1

Published: 2017-04 Ref. Modules: M3-11, M8-11
EN 16798-17

Energy performance of buildings — Ventilation for buildings — Part 17: Guidelines for inspection of ventilation and air conditioning systems

Published: 2017-06
Accompanying technical reportCEN/TR 16798-18

Energy performance of buildings — Ventilation for buildings — Interpretation of the requirements in EN 16798-17

Published: 2017-06 Ref. Modules: M4-11, M5-11, M6-11, M7-11
EN 16946-1

Energy performance of buildings — Inspection of Automation, Controls and Technical Building Management — Part 1

Published: 2017-07
Accompanying technical reportCEN/TR 16946-2

Inspection of Building Automation, Controls and Technical Building Management — Part 2: Accompanying prEN 16946-1:2015

Published: 2016-09 Ref. Modules: M10-11
EN 16947-1

Energy performance of buildings — Building Management System — Part 1

Published: 2017-06
Accompanying technical reportCEN/TR 16947-2

Building Management System — Part 2: Accompanying prEN 16947-1:2015

Published: 2016-09 Ref. Modules: M10-12

Stay Informed

Follow us on social media accounts to stay up to date with REHVA actualities

0

0 product in cart.products in cart.